LCP-000009 / Product configuration

Ball-Locking Hand-Mate Quick Coupler

A push-to-connect, ball-locking hand-mate coupling series illustrated by a CYSL04 reference, with documented body material and size range but unconfirmed seal and exact pressure-duty details.

Effective diameter options
DN3 to DN8
Body material
316 stainless steel
Listed operating temperature
-40 to +125 degC
Locking mechanism
Ball-locking push-to-connect mechanism

Technical selection

Specifications and configuration

Reference — CYSL

ParameterDocumented value / configuration
Effective diameter optionsDN3 to DN8Conditions: scope: series range; exact part needed
Body material316 stainless steelConditions: scope: body, not full wetted-material list
Locking mechanismBall-locking push-to-connect mechanismConditions: scope: manufacturer series description
Listed operating temperature-40 to +125 degCConditions: scope: website series summary; seals, coolant and pressure-temperature pairing not provided

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

A manually joined quick coupling with a ball-lock mechanism can create a serviceable coolant-line connection where a technician has access to both halves. The image is a CYSL04 series example, not proof of every diameter's geometry.

Construction and interfaces

The manufacturer identifies 316 stainless steel as the body material and describes a push-to-connect ball-lock arrangement. Seal grade, all wetted surfaces, end form and precise release method still depend on the chosen configuration.

Selection

Check the matched socket and plug, retention strength, connection and disconnection access, coolant chemistry, allowable pressure drop and installed temperature. A series-level temperature span is not a combined pressure-temperature-coolant rating.

Configuration options

The source lists DN3 through DN8 effective-diameter options. Select the actual size, mating ends, seals, mounting space and documentation as a coordinated pair; the photograph should not be used as a dimensional drawing.

Application limits

The source does not establish cross-manufacturer interchangeability, a leak-free disconnect, or suitability for a particular glycol concentration. Those claims require the exact controlled part and its tests.