Private previewCandidate · Draft · Noindex. Reference configuration; supply and public media use require confirmation.

LCP-000011 / Product configuration

Snap-On Latch Quick Coupler

A latch-locking push-to-connect coupling series illustrated by a CYCT05 unit, with a visible retention mechanism and supplier-described aluminum body but no inferred universal pressure or coolant rating.

Effective diameter options
DN3 to DN12
Body material
Aluminum alloy
Listed operating temperature
-40 to +125 degC
Locking mechanism
Latch-locking, push-to-lock engagement

Technical selection

Specifications and configuration

Reference — CYCT

ParameterDocumented value / configuration
Effective diameter optionsDN3 to DN12Conditions: scope: series range; exact part needed
Body materialAluminum alloyConditions: scope: body, not full wetted-material list
Locking mechanismLatch-locking, push-to-lock engagementConditions: scope: manufacturer series description
Listed operating temperature-40 to +125 degCConditions: scope: website series summary; seals, coolant and pressure-temperature pairing not provided

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

A snap-on, latch-locking quick coupler supports tool-light manual engagement where the mating halves and installation envelope are accessible. It is a different procurement choice from a ball-lock or guide-dependent blind-mate connector.

Construction and interfaces

The supplier identifies an aluminum-alloy body and a push-to-lock latch mechanism. The photographed CYCT05 reference shows the series style, while the actual seal, finish, wetted path and end configuration need exact drawings.

Selection

Review latch accessibility, release clearance and retention under pressure and handling loads. Match coolant chemistry, flow and pressure-drop duty to the selected socket and plug; the listing's broad temperature span alone is not a complete rating.

Configuration options

The manufacturer lists a DN3-to-DN12 diameter range. Specify one size, two end terminations, seal material, retention detail, mounting envelope and any protective cap or service accessory separately.

Application limits

Do not treat the pictured unit as all listed sizes or promise compatibility with an unspecified mating brand. Temperature, pressure and leakage must be assessed for the chosen configuration and test method.