LCP-000001 / Product configuration

UQD02-Format Hand-Mate Socket and Plug Configuration

A small-format valved quick-disconnect arrangement for serviceable liquid-loop connections; the pictured series is a visual reference, while interface and flow values belong to a documented UQD02 example.

Equivalent flow diameter
3 mm
Flow coefficient cv socket to plug
0.32
Flow coefficient cv plug to socket
0.33
Mating interface standard
FITOK states that its UQD series is designed and manufactured to the OCP UQD specification. The brochure does not identify a revision or establish cross-brand interchangeability for the pictured pair.
Socket plug end connection examples
UQD02-ST7-B socket and UQD02-ST7-D plug are separately listed with 7/16-20 UNF-2A SAE/MS straight-thread ends; UQD02-MP4-B is a separately listed 1/4 in hose-tail socket option.

Technical selection

Specifications and configuration

Reference — UQD02

ParameterDocumented value / configuration
Equivalent flow diameter3 mmConditions: scope: Equivalent flow diameter, not hose ID, mating-interface diameter or a universal UQD requirement.
Flow coefficient cv socket to plug0.32Conditions: direction: Socket to plug; scope: Cv coefficient; not a flow-rate rating.
Flow coefficient cv plug to socket0.33Conditions: direction: Plug to socket; scope: Cv coefficient; not a flow-rate rating.
Mating interface standardFITOK states that its UQD series is designed and manufactured to the OCP UQD specification. The brochure does not identify a revision or establish cross-brand interchangeability for the pictured pair.Conditions: scope: Manufacturer series claim; exact mating revision and fit require the selected pair's drawing
Socket plug end connection examplesUQD02-ST7-B socket and UQD02-ST7-D plug are separately listed with 7/16-20 UNF-2A SAE/MS straight-thread ends; UQD02-MP4-B is a separately listed 1/4 in hose-tail socket option.Conditions: scope: Listed end-connection examples, not a claim that the main photograph depicts any one code or that codes may be freely combined
Standard body and sealFITOK UQD series standard body material 304 stainless steel and standard seal EPDM; 316 and 316L stainless alternatives are available by request.Conditions: scope: Series material statement; selected plug/socket bill of materials and coolant compatibility require code-level confirmation
Series pressure temperature referenceFITOK brochure lists 16 bar maximum working pressure for UQD02 and a -20 to +150 °C working-temperature range for the UQD series.Conditions: scope: Manufacturer reference, not site supply or installed-loop rating; confirm coolant, seal, line ends and chosen order codes

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

This configuration pairs a manually operated socket and plug for a detachable coolant connection. It is distinct from blind-mate mounting because an operator must access and connect the two halves during installation or service.

Construction and interfaces

The reference illustration shows separate socket and plug bodies with different end geometries. End termination and mating-interface revision must be identified together; the image does not establish the size or order code of each pictured part.

Selection

FITOK's UQD02 table separately lists a 7/16-20 UNF-2A straight-thread socket and plug example and a 1/4 in hose-tail socket option. Specify both selected ends and the OCP UQD interface revision before checking coolant, flow direction, pressure drop and service access. The documented Cv values are coefficients, not rated loop flow.

Configuration options

The FITOK series reference lists a 304 stainless body and EPDM seal as standard, with 316/316L stainless alternatives by request. Select the socket and plug as a controlled pair; their end terminations, seals and wetted parts must match the actual order codes, not merely the main photograph.

Application limits

FITOK lists a 16 bar UQD02 maximum working-pressure reference and a -20 to +150 °C series temperature range, but the selected pair, seal, coolant and installed assembly require confirmation. The brochure gives no OCP interface revision or cross-brand mating test. The series photograph is an appearance reference, not proof of either listed end code or site supply.