Private previewCandidate · Draft · Noindex. Reference configuration; supply and public media use require confirmation.

LCP-000019 / Product configuration

UQD06 Red Hand-Mate Quick Disconnect Pair — CEJN Reference

A size-specific UQD06 socket and plug example using two CEJN red-coded part numbers; their different hose and thread ends are kept explicit rather than merged into a generic UQD specification.

End connections
Socket 1/2 inch hose connection; plug UNF 3/4-16
Nominal flow diameter
9.5 mm
Manufacturer max working pressure
10 bar
Listed seal material
EPDM
Documented mating part numbers
Red socket 10 153 1026; red plug 10 153 6676

Technical selection

Specifications and configuration

Reference — CEJN UQD06 red pair 10 153 1026 / 10 153 6676

ParameterDocumented value / configuration
Documented mating part numbersRed socket 10 153 1026; red plug 10 153 6676Conditions: scope: manufacturer order-code examples; pair and interface to be verified
End connectionsSocket 1/2 inch hose connection; plug UNF 3/4-16Conditions: scope: end-connection labels in the two UQD06 red rows; nominal hose designation is not a measured bore
Nominal flow diameter9.5 mmConditions: scope: these two UQD06 rows only; not a flow-rate guarantee
Manufacturer max working pressure10 barConditions: scope: manufacturer catalogue for specified red UQD06 parts; assembly conditions and coolant require review
Listed seal materialEPDMConditions: scope: these two UQD06 part numbers only

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

The UQD06 example is a manually mated, red-coded quick-disconnect pair for a data-center liquid line. The main and next gallery images show the separately identified socket and plug; the additional series group image provides context only.

Construction and interfaces

The documented socket has a 1/2-inch hose-side designation while its matching plug row uses a UNF 3/4-16 end. The interface and seal details have to be checked for the selected halves and mating arrangement.

Selection

The CEJN table assigns a 9.5 mm nominal flow diameter to the specified UQD06 rows. This is not a measured flow rate or pressure-drop promise; line sizing must use the required flow, coolant and the correct pair curve.

Configuration options

Other UQD sizes and red or blue identifiers occur in the source catalogue as separate order codes. Select the required size and orientation, hose/tube termination, colour convention and protective accessories without assuming visual similarity proves interchangeability.

Application limits

The manufacturer lists 10 bar maximum working pressure for these rows, but not an unlimited combined coolant-temperature envelope. No cross-brand mating or site supply capability is inferred from the UQD designation alone.