Private previewCandidate · Draft · Noindex. Reference configuration; supply and public media use require confirmation.

LCP-000113 / Product configuration

Compact Dual-Branch Server Node Distribution Assembly — BEEHE GB200 Reference

A compact node-level distribution layout with two separate corrugated connection legs. The maker's GB200 column lists two branches and a narrow 431.6 × 64.5 × 30.2 mm envelope.

Branch interface count
Two branches listed in the GB200 column
Body pipe material
SUS304 body and SUS316 piping listed in the GB200 column
Supply distribution mode
Manufacturer describes the inner-manifold family as generally using one inlet to distribute to multiple outlets; the GB200 column separately lists two branches. Exact supply/return pairing for a pictured build requires a drawing.
Branch external interfaces
NVQD04 branch interface and NVQD04 external interface, as listed in the GB200 platform column
Manufacturer pressure reference
10 bar stated as pressure-bearing reference in the GB200 platform column

Technical selection

Specifications and configuration

Reference — BEEHE GB200 node manifold reference

ParameterDocumented value / configuration
Branch interface countTwo branches listed in the GB200 column
Envelope dimensions431.6 × 64.5 × 30.2 mm listed in the GB200 column
Body pipe materialSUS304 body and SUS316 piping listed in the GB200 column
Supply distribution modeManufacturer describes the inner-manifold family as generally using one inlet to distribute to multiple outlets; the GB200 column separately lists two branches. Exact supply/return pairing for a pictured build requires a drawing.Conditions: scope: General manufacturer description, not a GB200 order-code hydraulic schematic or claim that both pictured legs are supply outlets
Mounting methodScrew mounting, as listed in the GB200 platform columnConditions: scope: Platform-column reference; hole pattern and mounting datums are not published
Branch external interfacesNVQD04 branch interface and NVQD04 external interface, as listed in the GB200 platform columnConditions: scope: Interface designations only; actual mating part numbers and revision require drawing confirmation
Manufacturer pressure reference10 bar stated as pressure-bearing reference in the GB200 platform columnConditions: scope: Manufacturer table only; working/test/burst basis and temperature/coolant conditions are not defined. Not a site supply or complete-loop rating

Manufacturer series reference. Confirm the exact order code, mating parts and stated conditions for the quoted configuration.

Overview

This two-branch node assembly is a different routing and interface purchase from the wide many-port header. It fits a narrower server-internal distribution role when matched to an approved chassis design.

Construction and interfaces

The second manufacturer gallery image depicts two slim corrugated branches with end fittings. The GB200 reference column lists SUS304 body material and SUS316 piping for its configuration.

Selection

The GB200 column lists two branches, NVQD04 at both the branch and external interfaces, screw mounting and a 431.6 × 64.5 × 30.2 mm envelope. The maker describes the inner-manifold family as generally distributing one inlet to multiple outlets; confirm the exact supply/return circuit, mating revisions, datums and clearances on a controlled drawing.

Configuration options

Confirm the mating quick-disconnect halves, mounting-hole pattern and tubing route for the ordered configuration. Do not treat one gallery image as a dimensioned or final installed assembly.

Application limits

The GB200 table states 10 bar as a pressure-bearing reference but gives no working/test/burst basis or temperature and coolant conditions. It is not a site or installed-loop rating. A platform label is not an order code or a claim of fit to every GB200 system; seal and leak-acceptance conditions remain configuration-specific.