Product family

Flow-Control Valves

Balancing, restricting, or controlling components for a stated operating range.

SMC FC2W520-X110 water flow controller — manufacturer catalogue product image; pictured suffix should be checked against the selected ordering code.
Representative component · configuration-specific

Component selection

All Product drafts

4 results
Private preview · candidate records

4 local draft records. Includes unfinished records and Family overviews. Draft · Noindex. Reference configurations are not approved stock. Image public-use review remains separate.

Show content-ready drafts
Lee compact flow-regulating valve insert, standalone manufacturer product photograph.

LCP-000086

Miniature Liquid Flow-Regulating Insert — Lee Reference

A non-adjustable flow-regulating valve insert for direct-to-chip liquid cooling. The product photograph shows the compact cartridge; separate diagrams illustrate fitting, hose and…

Regulated flow range
0.2–4 L/min listed range; higher flows require separate manufacturer configuration
Listed materials
303 stainless-steel body/cage; 302 stainless spring; CDA 360 brass poppet
View specifications

Specify with confidence

The details that shape your selection.

Balancing, restricting or modulating duty Required flow range and pressure-drop conditions Connection, material and actuation/interface requirements Failure state and calibration or verification needs Quantity and supporting assembly items

  • Function and loop position
  • Interfaces, drawing revisions and envelope
  • Coolant, materials and seals
  • Temperature, pressure and flow conditions
  • Testing and documentation
  • Quantities and delivery requirements

Overview

Flow-control valves support balancing, restriction or modulation of a defined branch. Selection depends on the required flow range and pressure differential, not just pipe size.

Configuration and selection

Specify duty, control or actuation interface, end connections, coolant and installation orientation. Define calibration, fail state and acceptance conditions for the proposed configuration.

Information to prepare

  • Balancing, restricting or modulating duty
  • Required flow range and pressure-drop conditions
  • Connection, material and actuation/interface requirements
  • Failure state and calibration or verification needs
  • Quantity and supporting assembly items

Configuration and quotation

Include the drawing or specification revision and identify any requirements that are still to be confirmed. Available configurations, testing and documentation are confirmed with quotation.

Documented reference configurations & supporting imagery

Local editorial preview

Documented configurations and product references

Manufacturer examples retain their model and conditions. These references describe source products, not approved stock or supply. Images are pending final selection and rights review.

Danfoss — CoolTrain

ParameterDocumented value / configuration
Functiondynamic hydronic balancing; precise flow control; motorized shut-off
ActuationMotorized shut-off with optional digital fieldbus actuator.
InterfaceReady-built rack-to-TCS valve-train assembly; exact connections are configuration-dependent.
Test conditionsThe described assembly is pre-assembled, pressure-tested, and cleaned; acceptance values are not provided on this page.

The Lee Company — Lee Flow Regulating Valve

ParameterDocumented value / configuration
Bore5.5 to 12 mm diameter product range

FITOK — ML series

ParameterDocumented value / configuration
Maximum flow coefficient cv0.15Conditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Orifice3.25 mmConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Stem taper6.5 degreeConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Opening turns10 to 11 turnsConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Flow patternsStraight and angle configurationsConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Handle optionsRound or vernier handle; panel mounting availableConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.
Shutoff functionListed for ML series; do not infer that every metering valve provides shutoffConditions: Attributed manufacturer series/configuration example only; not site stock or capability; scope: Manufacturer metering-valve example. Cv is a coefficient, not litres per minute or a guaranteed loop flow. Exact material, seal, fluid and operating conditions remain configuration-specific.

SMC — SMC FC2W520-04-3-X110

ParameterDocumented value / configuration
Ordering codeFC2W520-04-3-X110; 1/2 in. Rc port; 3 m leadConditions: scope: Exact catalogue ordering example
Rated flow control range2.0–16.0 L/minConditions: medium: Water; catalogue specified operating conditions
Process portRc 1/2Conditions: scope: Confirm mating thread and line size in RFQ
Working pressure0.2–0.4 MPa at 0–50 °C fluid temperature; proof pressure 0.6 MPaConditions: scope: Proof pressure is not the normal working range
Control accuracy±5% F.S. flow-control accuracy; response time ≤10 sConditions: scope: Catalogue condition; not a fast-acting safety shutoff
Power and signal24 VDC ±10%; 0–5 VDC analogue flow-command input; flow-pulse outputConditions: scope: Check controls integration and wiring diagram
Listed medium and temperatureWater; fluid temperature 0–50 °C without freezingConditions: scope: Do not infer glycol or other coolant compatibility from water rating
Shutoff limitationController cannot fully close; an external shutoff valve is needed for emergency stopConditions: scope: Functional boundary of FC2W-X110 series

The Lee Company — Flow Regulating Valve

ParameterDocumented value / configuration
FunctionNon-adjustable, pressure-compensating flow-regulating insert for chip/tray liquid cooling
Mounting optionsDL series into soft metal, press-in into plastic, or hose mount into EPDM/PTFE hose
Regulated flow range0.2–4 L/min listed range; higher flows require separate manufacturer configurationConditions: scope: series selection range, not the preset of pictured sample
Listed materials303 stainless-steel body/cage; 302 stainless spring; CDA 360 brass poppet

Configuration options and selection inputs

Flow direction

Regulated direction and mounting orientation must follow the exact valve configuration.

Reference: The Lee Company — Lee Flow Regulating Valve

Set pressure

Not a pressure-set valve: specified output is regulated flow rate, documented as 0.2 to 4 L/min or higher.

Reference: The Lee Company — Lee Flow Regulating Valve

Cracking pressure

Not the controlling selection parameter for this regulating-valve example; use stated differential-pressure regulation envelope and flow target.

Reference: The Lee Company — Lee Flow Regulating Valve

Test conditions

Manufacturer states 100% functional testing; RFQ must define fluid, target flow, differential-pressure range and acceptance tolerance.

Reference: The Lee Company — Lee Flow Regulating Valve